Wind Force Analysis of Intze Type Water Tank in Various Wind Zones Using STAAD-PRO
| Author(s) | : | Deepa Dubey, Satyendra Dubey, Y. K. Bajpai |
| Institution | : | Department of Civil Engineering Gyan Ganga Institute of Technology and Science, Jabalpur (M.P.), India. - 482003 |
| Published In | : | Vol. 4, Issue 6 — June 2017 |
| Page No. | : | 675-683 |
| Domain | : | Engineering |
| Type | : | Research Paper |
| ISSN (Online) | : | 2348-4470 |
| ISSN (Print) | : | 2348-6406 |
Overhead Intze type tank is a form of expanded water tank resting on staging. Bottom part of circular tank ofIntze tank is abounding in flat structure, thus in flat bottom, the thickness and reinforcement is set up to be high. Thiswork aims to study the performance of the Overhead water tank of Intze type under the action of basic wind loads indifferent terrain category. Commonly water tank is analysed as in step with the code IS 875 (element 3) and layout ofwater tank dome is executed as consistent with IS code 3370-1987 in working stress approach and the staging (columnand beams) are designed as per IS code 456-2000 in limit state method. In addition the present work deals with the Windanalysis of elevated INTZE type water tank using STAAD-Pro Software package. Wind study of reinforced concrete Intzetank is finished at one of a kind staging heights of tank with the aid of assuming to be located in exclusive wind zones inIndia of different terrain categories. Different parameters like as Design wind forces, displacements because of windforces at unique heights of water tank are in comparison in one of a kind wind zones
Deepa Dubey, Satyendra Dubey, Y. K. Bajpai, “Wind Force Analysis of Intze Type Water Tank in Various Wind Zones Using STAAD-PRO”, International Journal of Advance Engineering and Research Development (IJAERD), Vol. 4, Issue 6, pp. 675-683, June 2017.