Modification of Steam Stripper in DHDS Unit

Authors

  • Mehul Sonavdekar Department of Chemical Engineering, Bharati Vidyapeeth College of Engineering, Navi Mumbai
  • Aishwarya Sirpuram Department of Chemical Engineering, Bharati Vidyapeeth College of Engineering, Navi Mumbai
  • Vaibhav Zawar Department of Chemical Engineering, Bharati Vidyapeeth College of Engineering, Navi Mumbai
  • M. A. Suryawanshi Department of Chemical Engineering, Bharati Vidyapeeth College of Engineering, Navi Mumbai
  • V. B. Mane Department of Chemical Engineering, Bharati Vidyapeeth College of Engineering, Navi Mumba

Keywords:

Hydrodesulphurization, Salt drier, Vacuum drier, Sulphur removal

Abstract

The present work investigates the hydro treating process of a diesel to achieve low Sulphur content. The
main objective for removal of Sulphur from diesel is that it contributes to increased level of air pollution and equipment
corrosion. The objective of this project emphasizes to maintain Sulphur level about 40ppm, to ensure flash point about
77oC and to ensure less Sulphur content by using copper corrosion test. The steam stripper is used for removal of
hydrogen sulphide and ammonia. During feed steam stripping, there is an addition of moisture or water in diesel hence it
is sent to salt dryer where rock salt is present which absorbs moisture content from diesel. Due to very high consumption
of rock salt we are using a reboiler instead of a rock salt dryer. As reboiler is not efficient for removal of moisture we
replace reboiler with vacuum drier

Published

2017-04-25

How to Cite

Mehul Sonavdekar, Aishwarya Sirpuram, Vaibhav Zawar, M. A. Suryawanshi, & V. B. Mane. (2017). Modification of Steam Stripper in DHDS Unit. International Journal of Advance Engineering and Research Development (IJAERD), 4(4), 722–725. Retrieved from https://ijaerd.org/index.php/IJAERD/article/view/2650