Validation of Fracture Parameters using MTS Technology on certain Material.
Keywords:
J Intergral, ASTM 1820, SENB, MTSAbstract
It is important to work with new innovations and technologies with change of time. In similarmanner new
technologies can be used for carrying out validation of certain problems. It was conducted to investigate the effect of
specimen size on fracture toughness of mild steel. In this experiment, the specimen geometry was taken as a main
parameter to calculate the fracture toughness of mild steel. Thickness and Notch depth ratio these two parameters were
considered under specimen size. Specimen Geometry was referred from ASTM 1820 Standard code