Heat transfer phenomenon in vertical support of LAr jacketed tank
| Author(s) | : | B.L.Thakor |
| Institution | : | R.C.Technical Institute, Ahmedabad |
| Published In | : | Vol. 1, Issue 12 — December 2014 |
| Page No. | : | 226-229 |
| Domain | : | Engineering |
| Type | : | Research Paper |
| ISSN (Online) | : | 2348-4470 |
| ISSN (Print) | : | 2348-6406 |
Storage of LAr with minimum heat is the primary condition of storage tank. Boiling temperature of LAr is 87Kand surrounding ambient temperature is in the range of 293K to 313K C. This is quite vast temperature gradient. LArstorage tank is jacketed with outer tank with perlite insulation with required vacuum level In spite of insulation andvacuum, heat transfer takes place. There is thermal short between inner tank and outer tank through inner support.Heat inflow takes place trough this path to LAr and resulting in to vaporization of LAr. Study required in this area tounderstand the heat transfer phenomenon in LAr tank. Heat balance analysis gives the critical value of length ofconductive path
B.L.Thakor, “Heat transfer phenomenon in vertical support of LAr jacketed tank”, International Journal of Advance Engineering and Research Development (IJAERD), Vol. 1, Issue 12, pp. 226-229, December 2014.