Evaluation of Response Modification Factors for RCC Frame Structure
| Author(s) | : | Noor Ullah, Attaur Rahman |
| Institution | : | Department of Civil Engineering, University of Engineering and Technology Peshawar, Pakistan |
| Published In | : | Vol. 8, Issue 4 — April 2021 |
| Page No. | : | 1-5 |
| Domain | : | Engineering |
| Type | : | Research Paper |
| ISSN (Online) | : | 2348-4470 |
| ISSN (Print) | : | 2348-6406 |
This paper presents research carried out on beam column connections of Reinforced Concrete Structures toevaluate Response Modification Factors. R factors are important seismic design tools, which characterizes the level ofinelasticity expected in structural framework thought an earthquake incident. R factor reflects the capacity of structure todissipate energy through inelastic behavior. R factor is utilized to decrease the design forces in earthquake resistantdesign, accounts for energy dissipation capacity, damping and for over-strength of the structure. RCC beam columnconnections were subjected to quasi-static testing procedures and the data collected using data acquisition system wasanalyzed to compute structural parameters including R-factor. It has been concluded that Scatter value of R exists ascompared to a single value of R= 8.5 being adopted in BCP SP-07.
Noor Ullah, Attaur Rahman, “Evaluation of Response Modification Factors for RCC Frame Structure”, International Journal of Advance Engineering and Research Development (IJAERD), Vol. 8, Issue 4, pp. 1-5, April 2021.